Impact Window Ratings Explained: DP, NOA, SHGC, STC — What Every Florida Homeowner Needs to Know
The label on an impact window product sheet is full of acronyms. This guide decodes every number — in plain English — so you know exactly what you need for your county, your home's height, and your climate.
Quick Reference: What Each Rating Means
| Rating / Term | What It Measures | What's Good for Florida | Required? |
|---|---|---|---|
| DP (Design Pressure) | Wind load the window is rated for, + inward / − outward (psf) | Meets or exceeds the pressure calculated for each opening | Yes |
| NOA (Notice of Acceptance) | Miami-Dade product approval (HVHZ) | Standard proof of HVHZ approval in Miami-Dade and Broward | In the HVHZ (or FPA approved for HVHZ) |
| FPA (FL Product Approval) | Statewide impact product certification | Accepted statewide; in the HVHZ only if marked approved for HVHZ use | Yes (statewide) |
| SHGC | Solar heat passing through glass (0–1) | SHGC ≤ 0.23 for Energy Star; lower = cooler | For ENERGY STAR |
| U-Factor | Heat transfer rate (lower = more insulating) | ≤ 0.32 for ENERGY STAR Southern Zone | For ENERGY STAR |
| STC | Sound blocking ability (higher = quieter) | STC 38+ near airports/highways; 32+ baseline | No |
| VT (Visible Transmittance) | How much visible light passes through (0–1) | ≥ 0.40 for bright interiors; tinted = lower VT | No |
| PG (Performance Grade) | Grade earned only when structural, air and water tests all pass | PG50 includes DP50 plus air and water performance | Yes |
| Large Missile / Small Missile | Impact test type (debris simulation) | Large missile for windows within 30 ft of grade | By height |
What Is a DP Rating on Windows?
Often labeled DP, design pressure, or ± psf on labels and product approvals
A DP (design pressure) rating is the wind load, in pounds per square foot (psf), that a window or door is rated to resist. It is stated as two numbers: a positive value for wind pushing in on the glass and a negative value for suction pulling it out. A window labeled +80/−90 psf is rated for 80 psf inward and 90 psf outward. To pass the structural test of the North American Fenestration Standard (AAMA/WDMA/CSA 101/I.S.2/A440), the unit is loaded at its design pressure and then at 150% of it without failing. In Florida, the DP on the approval has to meet or exceed the design pressure calculated for that specific opening.
Positive vs. negative design pressure
- + Positive (inward): wind blowing straight at the wall pushes the glass in.
- − Negative (outward): wind flowing around the building creates suction that pulls the window out. Near wall corners and edges the suction is stronger, so the negative requirement is often the higher number.
- → Both numbers must be met. A +60/−50 window does not satisfy an opening that needs −55 psf, even though 60 is larger.
What DP50 and DP65 mean
DP50 means the product is rated for a 50 psf design pressure; its structural test was run at 75 psf (150%). DP65 means 65 psf, tested structurally at 97.5 psf. When only one number is shown, it usually applies in both directions; when two are shown (+65/−80), each direction has its own rating.
DP is not the same as PG. Under the same standard, a Performance Grade (for example, PG50) is earned only when the product also passes the air-leakage and water-penetration tests at that grade. DP is the structural number alone.
DP Rating Chart
The first chart shows what each common design pressure means in the structural test. The 150% factor comes from the North American Fenestration Standard for windows and doors.
| DP rating | Design pressure | Structural test load (150%) |
|---|---|---|
| DP30 | 30 psf | 45 psf |
| DP40 | 40 psf | 60 psf |
| DP50 | 50 psf | 75 psf |
| DP60 | 60 psf | 90 psf |
| DP65 | 65 psf | 97.5 psf |
| DP70 | 70 psf | 105 psf |
| DP80 | 80 psf | 120 psf |
| DP90 | 90 psf | 135 psf |
The second chart lists the published design pressure for the impact products in our catalog, taken from the manufacturers' catalog data. These are the highest published ratings; the approval can list lower values for larger sizes or other configurations, so always confirm the DP for your exact size.
| Product | Type | Design pressure (psf) | Miami-Dade NOA |
|---|---|---|---|
| ESR 1000 | Single Hung | +80/−90 | 24-1219.05 |
| ESR 1500 | Fixed / Picture | +70/−90 | 24-1219.07 |
| ESR 2000 | Horizontal Roller | +80/−90 | 24-1219.06 |
| ESR 3000 | French / Swing Door | +80/−70 | On request |
| ESR 4000 | Sliding Glass Door | +70/−80; OX/XO: +80/−103 | On request |
| ES-EL100 | Single Hung | +80/−80 | On request |
| ES-EL150 | Fixed / Picture | +80/−80 | On request |
| ES-EL200 | Horizontal Roller | +80/−90 | On request |
| ES-5000 | Casement | +90/−90 | On request |
| ES-EL300 | French / Swing Door | +80/−80 | On request |
| ES-EL400 | Sliding Glass Door | +80/−80 | On request |
How DP relates to wind zones and the HVHZ
There is no single "Florida DP." The Florida Building Code (8th Edition, 2023) determines wind loads with ASCE 7, Chapters 26 to 30 (Section 1609.1.1). The pressure on each opening depends on the design wind speed for the site, the exposure (open coast vs. built-up suburb), the height of the window, and where it sits on the wall — openings near corners see higher suction than the middle of a wall. That is why two windows on the same house can need different DP ratings.
Inside the High-Velocity Hurricane Zone (Miami-Dade and Broward), FBC Section 1620.2 sets the wind speed used in the calculation:
| County (HVHZ) | Risk Category I | Risk Category II (most homes) | Risk Category III | Risk Category IV |
|---|---|---|---|---|
| Miami-Dade | 165 mph | 175 mph | 186 mph | 195 mph |
| Broward | 156 mph | 170 mph | 180 mph | 185 mph |
These are 3-second-gust, strength-level (ultimate) wind speeds. Pressures calculated from them are converted to allowable-stress values (the 0.6 wind factor in ASCE 7's load combinations) before being compared with a product's DP — the engineer or the wind-load sheet in the permit package does that step. Palm Beach County is outside the HVHZ but inside the wind-borne debris region, where the wind speed comes from the FBC wind maps (Section 1609.3) for the exact site. In the HVHZ, glazing must also pass the large-missile impact test followed by cyclic pressure loading (FBC Section 1626, protocols TAS 201 and TAS 203), so an HVHZ approval shows the pressure the unit still held after being impacted.
How to read the DP on an NOA
- Match the product. Confirm the manufacturer, series and configuration (for example, a single hung "OX") are the ones being quoted.
- Find the design pressure table. Approvals list the positive and negative DP by size range, glass type and anchoring. Larger units usually carry lower ratings.
- Read your size, not the headline. Look up the row for your width and height and the glass in your quote. The headline number is the best case.
- Check the anchors and substrate. The rating holds only when the window is anchored as the approval shows (concrete, wood buck, etc.).
- Confirm it is current and HVHZ-approved where needed. In Miami-Dade and Broward, use a current Miami-Dade NOA or a Florida Product Approval marked approved for use in the HVHZ.
- Compare to the opening. Both the positive and negative values must meet or exceed what the permit's wind-load calculation requires for that opening.
Example: the ESR 1000 single hung is published at +80/−90 psf under Miami-Dade NOA 24-1219.05. If a permit required +45/−58 psf at a bedroom window, a size listed at +80/−90 in the NOA would clear it in both directions — the check is always against the NOA row for your exact size and glass.
Miami-Dade NOA vs Florida Product Approval: The Definitive Explanation
Miami-Dade NOA
(Notice of Acceptance)
Florida Product Approval
(FPA / FL Number)
| County | NOA sufficient? | FPA sufficient? | Both accepted? |
|---|---|---|---|
| Miami-Dade County (HVHZ) | ✅ Yes | Only if approved for HVHZ | ✅ Yes |
| Broward County (HVHZ) | ✅ Yes | Only if approved for HVHZ | ✅ Yes |
| Palm Beach County | ✅ Yes | ✅ Yes | ✅ Yes |
| All other FL counties | ✅ Yes | ✅ Yes | ✅ Yes |
SHGC and U-Factor: The Energy Ratings That Affect Your Electric Bill
SHGC — Solar Heat Gain Coefficient
Measures what fraction of solar radiation passes through the glass as heat. Scale: 0 to 1. Lower = less solar heat entering your home.
ENERGY STAR 2026 Southern Zone requires SHGC ≤ 0.23. Most quality impact glass is 0.23–0.27.
U-Factor — Thermal Insulation
Measures how quickly heat transfers through the glass. Lower = better insulation. In Florida, AC efficiency matters more than heating — but U-Factor still affects overall energy bills.
ENERGY STAR Southern Zone requirement (the zone Florida is in): U-Factor ≤ 0.32 and SHGC ≤ 0.23. Most standard impact glass does NOT qualify — must use Low-E.
Florida Rule: Never buy impact windows without Low-E glass in South Florida. Low-E is an upgrade priced with your sizes and options — Get your exact price.
STC Rating — Sound Transmission Class
STC measures how many decibels of sound a window blocks. It's not a code requirement in Florida — but it matters enormously if you're near FLL airport, I-95, or Tri-Rail.
| Glass Type | Typical STC | What You'll Hear | Good For |
|---|---|---|---|
| Regular single-pane glass | STC 26–28 | Loud speech audible | Quiet suburban areas only |
| Standard laminated impact glass | STC 32–38 | Speech muffled; traffic subdued | Most Florida neighborhoods |
| Laminated Low-E impact glass | STC 35–42 | Speech barely audible; traffic quiet | Near busy roads, transit |
| Laminated IGU (insulated unit) | STC 42–50 | Only loud trucks barely heard | Near airports, major highways |
| Acoustic laminated IGU (specialty) | STC 48–55 | Near-silence indoors | FLL/MIA approach path, I-95 frontage |
Note: IGU = Insulated Glass Unit (two panes with air or argon space). IGU impact windows cost more but deliver significantly better STC and U-Factor performance. Most in-stock WSM inventory is laminated single-pane — specify IGU if noise is a priority.
VT (Visible Transmittance) — How Bright Is Your Home?
VT measures what fraction of visible light passes through glass. Scale: 0 to 1. Higher = brighter interior. It's often the rating homeowners forget about — then complain their home feels dark after window installation.
Bronze, gray, charcoal tints. Very low solar heat gain but dim interiors. Better for west-facing windows in hot climates.
Light bronze or blue-green tint. Good energy performance + reasonably bright interior. Most standard Low-E impact glass falls here.
Nearly clear glass. Maximum natural light. Higher SHGC than tinted options but best aesthetics. Good for north-facing and interior rooms.
What You Actually Need: By County
Miami-Dade County
- ✓Current Miami-Dade NOA, or FPA marked approved for HVHZ
- ✓Design pressure per opening from the permit wind-load calculation (175 mph, Risk Category II)
- ✓Large missile test for ground/near-grade
- ✓SHGC ≤ 0.27 recommended (Low-E)
- ✓Licensed FL contractor required
- ✓Building permit required — no exceptions
Broward County
- ✓Inside the HVHZ — HVHZ-approved product required
- ✓Miami-Dade NOA is the standard proof of HVHZ approval
- ✓Design pressure per opening from the permit wind-load calculation (170 mph, Risk Category II)
- ✓SHGC ≤ 0.27 recommended
- ✓Licensed FL contractor required
- ✓Building permit required
Palm Beach County
- ✓Outside the HVHZ; inside the wind-borne debris region
- ✓Current Florida Product Approval or NOA
- ✓Design pressure per opening from the FBC wind map for the site
- ✓SHGC ≤ 0.27 for Energy Star
- ✓Licensed FL contractor required
- ✓Building permit required
- ✓Wind mitigation inspection for insurance discount
Which Impact Window Ratings Matter Most? A Priority Checklist
Impact window ratings are the numbers on the product approval and label that describe storm strength, energy performance, sound, and light. Not all carry the same weight. Check them in this order.
| Priority | Rating | What it decides |
|---|---|---|
| 1. Must-have | NOA / Florida Product Approval | Whether the product can be permitted at all |
| 1. Must-have | Design pressure (DP / PG) | Whether it meets the wind load your permit requires |
| 1. Must-have | Missile impact level | Whether it meets the debris-impact requirement for the opening |
| 2. Comfort and cost | SHGC and U-factor | Heat gain and energy use with your A/C |
| 3. Nice to have | STC | How much outside noise is blocked |
| 3. Nice to have | VT | How much daylight gets through the glass |
Common Mistakes When Comparing Window Ratings
- Comparing ratings across different sizes. Ratings are approved per model and size range. A rating on a small unit does not automatically apply to a larger one.
- Treating energy ratings as storm ratings. A low SHGC says nothing about hurricane strength.
- Trusting a marketing claim without an approval number. Ask for the NOA or FPA and check the model against it.
- Buying more DP than your permit requires. Match the requirement; extra margin can add cost.
- Ignoring glass options. Different glass packages can change SHGC, STC, and price on the same frame.
Compare Real Products and Prices
Windows Stock Market lists in-stock PGT, ESW, and Mr. Glass impact windows with a price per item by size, color, and glass. Use the instant price tool or browse the marketplace to line up the ratings against the price. Related guides: impact window permits (we coordinate the permit process), PGT vs ESW vs Mr. Glass, 2026 cost guide, and hurricane vs impact windows.
Frequently Asked Questions
What DP rating do I need for impact windows in Florida?↓
What does SHGC mean and what SHGC should I choose in Florida?↓
What is an STC rating for impact windows?↓
What is the difference between Miami-Dade NOA and Florida Product Approval?↓
What is a large missile vs small missile impact test?↓
What does 'PG' (Performance Grade) mean on impact windows?↓
What is a DP rating on windows?↓
What does DP50 mean on a window?↓
What ratings matter most on an impact window?↓
How do I read the label on an impact window?↓
Is a higher DP rating always better?↓
Need Help Choosing the Right Rated Impact Windows?
Vieser Construction provides free estimates with full specification details — DP ratings, NOA/FPA documentation, SHGC values, and STC performance. We take care of the technical side so you don't have to.