    Quick Reference: What Each Rating Means

    Rating / TermWhat It MeasuresWhat's Good for FloridaRequired?
    DP (Design Pressure)Wind load the window is rated for, + inward / − outward (psf)Meets or exceeds the pressure calculated for each openingYes
    NOA (Notice of Acceptance)Miami-Dade product approval (HVHZ)Standard proof of HVHZ approval in Miami-Dade and BrowardIn the HVHZ (or FPA approved for HVHZ)
    FPA (FL Product Approval)Statewide impact product certificationAccepted statewide; in the HVHZ only if marked approved for HVHZ useYes (statewide)
    SHGCSolar heat passing through glass (0–1)SHGC ≤ 0.23 for Energy Star; lower = coolerFor ENERGY STAR
    U-FactorHeat transfer rate (lower = more insulating)≤ 0.32 for ENERGY STAR Southern ZoneFor ENERGY STAR
    STCSound blocking ability (higher = quieter)STC 38+ near airports/highways; 32+ baselineNo
    VT (Visible Transmittance)How much visible light passes through (0–1)≥ 0.40 for bright interiors; tinted = lower VTNo
    PG (Performance Grade)Grade earned only when structural, air and water tests all passPG50 includes DP50 plus air and water performanceYes
    Large Missile / Small MissileImpact test type (debris simulation)Large missile for windows within 30 ft of gradeBy height

    What Is a DP Rating on Windows?

    Often labeled DP, design pressure, or ± psf on labels and product approvals

    A DP (design pressure) rating is the wind load, in pounds per square foot (psf), that a window or door is rated to resist. It is stated as two numbers: a positive value for wind pushing in on the glass and a negative value for suction pulling it out. A window labeled +80/−90 psf is rated for 80 psf inward and 90 psf outward. To pass the structural test of the North American Fenestration Standard (AAMA/WDMA/CSA 101/I.S.2/A440), the unit is loaded at its design pressure and then at 150% of it without failing. In Florida, the DP on the approval has to meet or exceed the design pressure calculated for that specific opening.

    Positive vs. negative design pressure

    • + Positive (inward): wind blowing straight at the wall pushes the glass in.
    • − Negative (outward): wind flowing around the building creates suction that pulls the window out. Near wall corners and edges the suction is stronger, so the negative requirement is often the higher number.
    • → Both numbers must be met. A +60/−50 window does not satisfy an opening that needs −55 psf, even though 60 is larger.

    What DP50 and DP65 mean

    DP50 means the product is rated for a 50 psf design pressure; its structural test was run at 75 psf (150%). DP65 means 65 psf, tested structurally at 97.5 psf. When only one number is shown, it usually applies in both directions; when two are shown (+65/−80), each direction has its own rating.

    DP is not the same as PG. Under the same standard, a Performance Grade (for example, PG50) is earned only when the product also passes the air-leakage and water-penetration tests at that grade. DP is the structural number alone.

    DP Rating Chart

    The first chart shows what each common design pressure means in the structural test. The 150% factor comes from the North American Fenestration Standard for windows and doors.

    DP ratingDesign pressureStructural test load (150%)
    DP3030 psf45 psf
    DP4040 psf60 psf
    DP5050 psf75 psf
    DP6060 psf90 psf
    DP6565 psf97.5 psf
    DP7070 psf105 psf
    DP8080 psf120 psf
    DP9090 psf135 psf

    The second chart lists the published design pressure for the impact products in our catalog, taken from the manufacturers' catalog data. These are the highest published ratings; the approval can list lower values for larger sizes or other configurations, so always confirm the DP for your exact size.

    ProductTypeDesign pressure (psf)Miami-Dade NOA
    ESR 1000Single Hung+80/−9024-1219.05
    ESR 1500Fixed / Picture+70/−9024-1219.07
    ESR 2000Horizontal Roller+80/−9024-1219.06
    ESR 3000French / Swing Door+80/−70On request
    ESR 4000Sliding Glass Door+70/−80; OX/XO: +80/−103On request
    ES-EL100Single Hung+80/−80On request
    ES-EL150Fixed / Picture+80/−80On request
    ES-EL200Horizontal Roller+80/−90On request
    ES-5000Casement+90/−90On request
    ES-EL300French / Swing Door+80/−80On request
    ES-EL400Sliding Glass Door+80/−80On request

    How DP relates to wind zones and the HVHZ

    There is no single "Florida DP." The Florida Building Code (8th Edition, 2023) determines wind loads with ASCE 7, Chapters 26 to 30 (Section 1609.1.1). The pressure on each opening depends on the design wind speed for the site, the exposure (open coast vs. built-up suburb), the height of the window, and where it sits on the wall — openings near corners see higher suction than the middle of a wall. That is why two windows on the same house can need different DP ratings.

    Inside the High-Velocity Hurricane Zone (Miami-Dade and Broward), FBC Section 1620.2 sets the wind speed used in the calculation:

    County (HVHZ)Risk Category IRisk Category II (most homes)Risk Category IIIRisk Category IV
    Miami-Dade165 mph175 mph186 mph195 mph
    Broward156 mph170 mph180 mph185 mph

    These are 3-second-gust, strength-level (ultimate) wind speeds. Pressures calculated from them are converted to allowable-stress values (the 0.6 wind factor in ASCE 7's load combinations) before being compared with a product's DP — the engineer or the wind-load sheet in the permit package does that step. Palm Beach County is outside the HVHZ but inside the wind-borne debris region, where the wind speed comes from the FBC wind maps (Section 1609.3) for the exact site. In the HVHZ, glazing must also pass the large-missile impact test followed by cyclic pressure loading (FBC Section 1626, protocols TAS 201 and TAS 203), so an HVHZ approval shows the pressure the unit still held after being impacted.

    How to read the DP on an NOA

    1. Match the product. Confirm the manufacturer, series and configuration (for example, a single hung "OX") are the ones being quoted.
    2. Find the design pressure table. Approvals list the positive and negative DP by size range, glass type and anchoring. Larger units usually carry lower ratings.
    3. Read your size, not the headline. Look up the row for your width and height and the glass in your quote. The headline number is the best case.
    4. Check the anchors and substrate. The rating holds only when the window is anchored as the approval shows (concrete, wood buck, etc.).
    5. Confirm it is current and HVHZ-approved where needed. In Miami-Dade and Broward, use a current Miami-Dade NOA or a Florida Product Approval marked approved for use in the HVHZ.
    6. Compare to the opening. Both the positive and negative values must meet or exceed what the permit's wind-load calculation requires for that opening.

    Example: the ESR 1000 single hung is published at +80/−90 psf under Miami-Dade NOA 24-1219.05. If a permit required +45/−58 psf at a bedroom window, a size listed at +80/−90 in the NOA would clear it in both directions — the check is always against the NOA row for your exact size and glass.

    Miami-Dade NOA vs Florida Product Approval: The Definitive Explanation

    🏛️

    Miami-Dade NOA
    (Notice of Acceptance)

    Issued by: Miami-Dade Building Department
    Number format: 23-0101.04 (year-sequence.revision)
    Search: miamidade.gov/building (product control)
    Used in: the HVHZ (Miami-Dade and Broward) as the standard proof of HVHZ approval
    Accepted in: Florida counties outside the HVHZ as well
    Testing standard: TAS 201/202/203 + ASTM E1996
    Expiration: Typically 5 years; must be current at time of install
    A current NOA covering the exact product, size and anchoring is accepted in the HVHZ; the building department confirms the final documentation.
    🏠

    Florida Product Approval
    (FPA / FL Number)

    Issued by: FL Dept of Business & Professional Regulation
    Number format: FL12345.1 (FL + digits + revision)
    Search: floridabuilding.org/pr/pr_app_lst.aspx
    Used in: Palm Beach and other counties outside the HVHZ
    In the HVHZ: only when the approval is marked approved for use in the HVHZ
    Testing standard: ASTM E1886/E1996 + FBC TAS
    Expiration: Reviewed periodically; check for active status
    In Miami-Dade and Broward, an FL number counts only if the approval says "Approved for use in HVHZ: Yes" and is current. Expired, withdrawn or non-HVHZ approvals do not qualify.
    CountyNOA sufficient?FPA sufficient?Both accepted?
    Miami-Dade County (HVHZ)✅ YesOnly if approved for HVHZ✅ Yes
    Broward County (HVHZ)✅ YesOnly if approved for HVHZ✅ Yes
    Palm Beach County✅ Yes✅ Yes✅ Yes
    All other FL counties✅ Yes✅ Yes✅ Yes

    SHGC and U-Factor: The Energy Ratings That Affect Your Electric Bill

    SHGC — Solar Heat Gain Coefficient

    Measures what fraction of solar radiation passes through the glass as heat. Scale: 0 to 1. Lower = less solar heat entering your home.

    Clear glass (no Low-E)0.82–0.86
    Basic tinted glass0.55–0.70
    Low-E impact glass (standard)0.27–0.35
    Low-E impact glass (high perf.)0.23–0.27
    Spectrally selective Low-E0.18–0.23

    ENERGY STAR 2026 Southern Zone requires SHGC ≤ 0.23. Most quality impact glass is 0.23–0.27.

    U-Factor — Thermal Insulation

    Measures how quickly heat transfers through the glass. Lower = better insulation. In Florida, AC efficiency matters more than heating — but U-Factor still affects overall energy bills.

    Single-pane impact glass0.90–1.10
    Laminated impact (single-pane)0.85–1.00
    Low-E laminated (standard)0.40–0.55
    Low-E IGU (insulated unit)0.28–0.40
    Triple-pane Low-E IGU0.15–0.28

    ENERGY STAR Southern Zone requirement (the zone Florida is in): U-Factor ≤ 0.32 and SHGC ≤ 0.23. Most standard impact glass does NOT qualify — must use Low-E.

    Florida Rule: Never buy impact windows without Low-E glass in South Florida. Low-E is an upgrade priced with your sizes and options — Get your exact price.

    STC Rating — Sound Transmission Class

    STC measures how many decibels of sound a window blocks. It's not a code requirement in Florida — but it matters enormously if you're near FLL airport, I-95, or Tri-Rail.

    Glass TypeTypical STCWhat You'll HearGood For
    Regular single-pane glassSTC 26–28Loud speech audibleQuiet suburban areas only
    Standard laminated impact glassSTC 32–38Speech muffled; traffic subduedMost Florida neighborhoods
    Laminated Low-E impact glassSTC 35–42Speech barely audible; traffic quietNear busy roads, transit
    Laminated IGU (insulated unit)STC 42–50Only loud trucks barely heardNear airports, major highways
    Acoustic laminated IGU (specialty)STC 48–55Near-silence indoorsFLL/MIA approach path, I-95 frontage

    Note: IGU = Insulated Glass Unit (two panes with air or argon space). IGU impact windows cost more but deliver significantly better STC and U-Factor performance. Most in-stock WSM inventory is laminated single-pane — specify IGU if noise is a priority.

    VT (Visible Transmittance) — How Bright Is Your Home?

    VT measures what fraction of visible light passes through glass. Scale: 0 to 1. Higher = brighter interior. It's often the rating homeowners forget about — then complain their home feels dark after window installation.

    VT 0.10–0.35
    Dark / Heavily Tinted

    Bronze, gray, charcoal tints. Very low solar heat gain but dim interiors. Better for west-facing windows in hot climates.

    VT 0.40–0.60
    Balanced — Most FL Homes

    Light bronze or blue-green tint. Good energy performance + reasonably bright interior. Most standard Low-E impact glass falls here.

    VT 0.60–0.70+
    Bright / Clear Appearance

    Nearly clear glass. Maximum natural light. Higher SHGC than tinted options but best aesthetics. Good for north-facing and interior rooms.

    What You Actually Need: By County

    Miami-Dade County

    • ✓Current Miami-Dade NOA, or FPA marked approved for HVHZ
    • ✓Design pressure per opening from the permit wind-load calculation (175 mph, Risk Category II)
    • ✓Large missile test for ground/near-grade
    • ✓SHGC ≤ 0.27 recommended (Low-E)
    • ✓Licensed FL contractor required
    • ✓Building permit required — no exceptions

    Broward County

    • ✓Inside the HVHZ — HVHZ-approved product required
    • ✓Miami-Dade NOA is the standard proof of HVHZ approval
    • ✓Design pressure per opening from the permit wind-load calculation (170 mph, Risk Category II)
    • ✓SHGC ≤ 0.27 recommended
    • ✓Licensed FL contractor required
    • ✓Building permit required

    Palm Beach County

    • ✓Outside the HVHZ; inside the wind-borne debris region
    • ✓Current Florida Product Approval or NOA
    • ✓Design pressure per opening from the FBC wind map for the site
    • ✓SHGC ≤ 0.27 for Energy Star
    • ✓Licensed FL contractor required
    • ✓Building permit required
    • ✓Wind mitigation inspection for insurance discount

    Which Impact Window Ratings Matter Most? A Priority Checklist

    Impact window ratings are the numbers on the product approval and label that describe storm strength, energy performance, sound, and light. Not all carry the same weight. Check them in this order.

    PriorityRatingWhat it decides
    1. Must-haveNOA / Florida Product ApprovalWhether the product can be permitted at all
    1. Must-haveDesign pressure (DP / PG)Whether it meets the wind load your permit requires
    1. Must-haveMissile impact levelWhether it meets the debris-impact requirement for the opening
    2. Comfort and costSHGC and U-factorHeat gain and energy use with your A/C
    3. Nice to haveSTCHow much outside noise is blocked
    3. Nice to haveVTHow much daylight gets through the glass

    Common Mistakes When Comparing Window Ratings

    • Comparing ratings across different sizes. Ratings are approved per model and size range. A rating on a small unit does not automatically apply to a larger one.
    • Treating energy ratings as storm ratings. A low SHGC says nothing about hurricane strength.
    • Trusting a marketing claim without an approval number. Ask for the NOA or FPA and check the model against it.
    • Buying more DP than your permit requires. Match the requirement; extra margin can add cost.
    • Ignoring glass options. Different glass packages can change SHGC, STC, and price on the same frame.

    Compare Real Products and Prices

    Windows Stock Market lists in-stock PGT, ESW, and Mr. Glass impact windows with a price per item by size, color, and glass. Use the instant price tool or browse the marketplace to line up the ratings against the price. Related guides: impact window permits (we coordinate the permit process), PGT vs ESW vs Mr. Glass, 2026 cost guide, and hurricane vs impact windows.

    Frequently Asked Questions

    What DP rating do I need for impact windows in Florida?↓
    There is no single Florida minimum. The Florida Building Code determines wind loads with ASCE 7, so the required design pressure is calculated per opening from the site wind speed, exposure, window height and position on the wall (corners see higher suction). In the HVHZ, FBC Section 1620.2 sets the wind speed: 175 mph in Miami-Dade and 170 mph in Broward for Risk Category II buildings such as most homes. The permit's wind-load calculation gives the positive and negative pressure each window must meet or exceed.
    What does SHGC mean and what SHGC should I choose in Florida?↓
    SHGC (Solar Heat Gain Coefficient) measures how much solar heat passes through the glass. A value of 0.0 blocks all solar heat; 1.0 passes all heat. In Florida's hot climate, lower is better. ENERGY STAR requires SHGC ≤ 0.23 for the Southern Climate Zone. Most Low-E impact glass offers SHGC 0.23–0.27. Clear impact glass (no Low-E) runs SHGC 0.82–0.86 — much higher energy costs. Always choose Low-E glass in Florida.
    What is an STC rating for impact windows?↓
    STC (Sound Transmission Class) measures how well a window blocks sound. Higher is better: STC 28–32 is typical for single-pane regular glass; STC 35–42 is typical for laminated impact glass; STC 45–55 is achievable with laminated insulated glass (IGU). If you're near an airport, highway, or busy road in South Florida, look for STC 38+ in your impact windows.
    What is the difference between Miami-Dade NOA and Florida Product Approval?↓
    Both are approval systems for impact-resistant products. A Miami-Dade NOA (Notice of Acceptance) is issued by Miami-Dade's product control office; a Florida Product Approval (FL number) is issued through the state's product approval system. Inside the High-Velocity Hurricane Zone (Miami-Dade and Broward), use a current Miami-Dade NOA or a Florida Product Approval explicitly marked approved for use in the HVHZ. Outside the HVHZ, such as Palm Beach County, a current Florida Product Approval or NOA for the product is used. The local building department sets the final documentation.
    What is a large missile vs small missile impact test?↓
    Large missile impact test (TAS 201): a 9-lb 2×4 wood plank is fired at the window at 50 ft/sec (~34 mph). Required for windows within 30 feet of grade level. Small missile impact test (TAS 201 small): 10 steel ball bearings are fired at the window at 80 ft/sec. Used for windows above 30 feet in some jurisdictions. Most residential impact windows pass the large missile test — verify the product's test certificate matches your installation height.
    What does 'PG' (Performance Grade) mean on impact windows?↓
    PG (Performance Grade) comes from the North American Fenestration Standard (AAMA/WDMA/CSA 101/I.S.2/A440). A product earns a PG only when it passes the structural test and the air-leakage and water-penetration tests at that grade, so PG50 says more than DP50. DP (design pressure) is the structural rating alone. For a Florida permit, the design pressure on the approval must meet or exceed the pressure calculated for the opening.
    What is a DP rating on windows?↓
    A DP (design pressure) rating is the wind load, in pounds per square foot (psf), that a window or door is rated to resist. It has a positive value (wind pushing in) and a negative value (suction pulling out), for example +80/-90 psf. Under the North American Fenestration Standard the unit must also hold 150% of its design pressure in the structural test. In Florida the rating must meet or exceed the design pressure calculated for each opening.
    What does DP50 mean on a window?↓
    DP50 means the window is rated for a 50 psf design pressure and passed a structural test at 75 psf (150% of DP). DP65 means 65 psf, tested at 97.5 psf. When a single number is shown it usually applies to both positive and negative pressure; when two are shown, each direction has its own rating.
    What ratings matter most on an impact window?↓
    For safety and permitting, three things matter most: the product approval (Miami-Dade NOA or Florida Product Approval), the design pressure (DP or PG) that meets your permit requirement, and the missile impact level. SHGC, U-factor, STC, and VT affect energy use, noise, and light, so they matter for comfort and cost but do not replace the approval.
    How do I read the label on an impact window?↓
    Look for the manufacturer and model, the approval number (NOA or FPA), the design pressure or PG value, the missile level, and the glass type. Then match the exact model and size to the approval document. Ask for the approval before you order; a legitimate product will have one.
    Is a higher DP rating always better?↓
    Not necessarily. You need a rating that meets or exceeds the requirement for your opening, as set by your permit package. A higher rating can cost more and can be limited to certain sizes, so paying for more than the requirement buys extra margin, not extra compliance.

    Need Help Choosing the Right Rated Impact Windows?

    Vieser Construction provides free estimates with full specification details — DP ratings, NOA/FPA documentation, SHGC values, and STC performance. We take care of the technical side so you don't have to.

    Verify the NOA against the actual surplus unit

    For a clearance or marketplace purchase, obtain the product approval number before reserving if it is not shown in the listing. Look it up in Miami-Dade Product Control and match the manufacturer, series, tested configuration and permitted size—not a similar-looking window.

    Keep the manufacturer label and the approval document with the project paperwork. A marking is a starting point for verification, not a substitute for checking that the current approval covers the glass, frame, hardware and anchoring of the unit being purchased.

    We use optional cookies for analytics and advertising. They are not needed to browse or buy. Privacy